    Y-type filter is an indispensable filtering device in the pipeline system for conveying media. It's usually installed at the inlet end of pressure reducing valve, pressure relief valve, water level valve or other equipment to remove impurities in the medium to protect the normal use of valves and equipment.


1. Working Principle

    A small device used to remove solids from liquids. Its main function is to protect the normal operation of compressors, pumps and other equipment and instruments, so as to stabilize the process and ensure safety. The filter intercepts impurities in the medium through the filter screen, allowing the clean fluid to pass through the filter screen into the connecting valve and pipeline, while the debris remains in the filter barrel.


2. Product Features

(1) Double-layer mesh structure: It adopts a stainless steel double-layer mesh structure, which is sturdy and durable, with advanced structure, small flow resistance, convenient sewage discharge, and large sewage holding capacity.

(2) Wide range of applicable media: The applicable media can be water, oil, and gas. The water mesh is 18-30 mesh/cm², the air mesh is 40-100 mesh/cm², and the oil mesh is 100-480 mesh/cm².

(3) Easy maintenance: When cleaning is required, just take out the detachable filter cartridge, remove the filtered impurities, and reinstall it.


3. Application fields

    GL11W stainless steel Y-type filter is widely used in chemical, petroleum, papermaking, mining, electricity, liquefied gas, food, pharmaceutical, water supply and drainage, municipal administration, mechanical equipment supporting, electronic industry, urban construction and other fields.


4. Structural features

(1) Small resistance and convenient flushing: It has the characteristics of small structural resistance, convenient flushing and fast flow, so it has small pressure loss, strong anti-fouling and convenient slag discharge.

(2) Pull rod telescopic design: The Y-type pull rod telescopic filter consists of a Y-type filter and a telescopic joint, which is convenient for cleaning debris and installation and disassembly, and protects the normal use of valves or equipment.


5. Main Parts

(1) Shell material: carbon steel WCB, brass B62, stainless steel 304, 316, 316L.

(2) Filter frame and filtermesh material: stainless steel 304, 316, 316L.

(3) Seal material: oil-resistant asbestos, NBR nitrile rubber, PTFE etc.



| Size              

GL11W Y-type Filter
SIZE DN D L+_1.5 H Weight(kg)
1/4'' 8 8 54 35 0.135
3/8'' 10 10 54 35 0.12
1/2'' 15 15 59 40 0.155
3/4'' 20 20 75 55 0.275
1'' 25 25 83 58 0.355
1 1/4'' 32 32 100 68 0.55
1 1/2'' 40 40 106 78 0.73
2'' 50 50 123 96 1.235


| Vertical check valve parameter table


Product name GL11W Y Filter
Connection Female Thread End: BSPT, NPT, DIN2999
Material CF3, CF3M, CF8, CF8M etc
Size DN8 - DN50
Class 1.6MPa, 2.5MPa, 4.0MPa
Temperature 0~300℃
Media W.O.G etc.
General Standard Design standard: GB/T 12221-2005
Pressure - Temperature Class: GB/T 12224-2005
Flange ends standard: GB/T 9113
Test standard: GB/T 13927-2008



| FAQ


I.  Difference Steps for cleaning Y filter


(1) Close the valve: Before cleaning, first close the inlet and outlet valves connected to the Y-type filter to stop the flow of fluid and ensure safety.


(2) Disassemble the filter: Depending on the specific model and design, the Y-type filter can be disassembled using bolts or other connectors.


(3) Remove residue: After removing the filter basket, rinse the filter basket and internal channels with clean water or an appropriate solution to remove residual particles and dirt. A soft brush or compressed air can be used to assist in cleaning.


(4) Check and replace the filter screen: Check whether the filter screen in the filter basket is damaged or blocked. If damaged or blocked, replace it with a new filter screen in time. Ensure that the quality and accuracy of the filter screen meet the requirements.


(5) Reassemble: After cleaning the filter basket and replacing the filter screen, return the filter basket to the Y-type filter position and ensure that it is installed correctly. Reinstall any seals and connectors to ensure that they are firmly tightened.


(6) Install back: Install the filter back into the pipeline, open the valve, and resume operation.

Y filter2

II. Disassembling Y-Type Filter: Key Precautions


(1) Turn off the fluid source

Before starting the disassembly and maintenance, you must firstly turn off the liquid or gas fluid source supplying the Y type strainer to prevent fluid leakage or splashing.


(2) Releasw the pressure

If there is pressure inside the Y strainer, you should release the pressure to avoid accidents. It can be achieved by opening the exhaust valve or screw to release the air.


(3) Wear labor protection equipment

Operators should wear labor protection equipment, such as protective gloves, glasses or masks, ensing personal safety.


(4) Confirm that system pressure drops to zero

During operation or maintenance, please not that gauge pressure drops to zero and the product temperature drops to room temperature before procedding, otherwise it's easy to casue personal injury.


(5) Confirm the medium in the pipeline has been blocked


(6) Use the correct tools

Using the corresponding tools such as wrenches or screwdrivers to remove the upper and lower covers of the Y filter, sometimes may requre additional scres or butterfly bolts to disassemble.


(7) Check the filter mesh and sealing gasket

If the filter mesh is damaged or blocked, it needs to be cleaned or replaced. Check the upper and lower covers and the sealing gaskets at the connection parts.


(8) Avoid damage to surrounding pipes and equipment


(9) Check the connecting pipes

Before reinstalling the Y type filter, check the connection parts between the filter and pipes and ensure there are no leakage.


(10) Follow the operating manual or consult professionals





Previous: 
Next: 

Product Category

Contact Us

Add : China Electronics Information Port, Binhai 13th Road, Longwan District, Wenzhou City, Zhejiang Province, China
Tel : +8619884668418
E-mail :  Admin@wzdejia.cn
                 Katherine@wzdejia.cn
Whats : +8619884668418
  • China Electronics Information Port, Binhai 13th Road, Longwan District, Wenzhou City, Zhejiang Province, China
  • E-email us:
    Admin@wzdejia.cn
  • Call us on:
    +86 19884668418